Page 124 - 2017-Swift-Group-Motorhomes-Handbook-web
P. 124
1 – 5 - S witch lighting on. Service menu FITTED EQUIPMENT
Brightness selectable in 5 levels.
1. Calibrating the room temperature
OFF - Switch lighting off. sensor of the heater (OFFSET)
• T ap the rotary push button to confirm the The room temperature sensor of the heater
value. can be individually adjusted to the sensor’s
installation situation. The setting can be made
in increments of 0.5°C within the range of 0°C
to -5°C.
Set time Example:
24hour mode
Set room temperature 23 °C;
12hour mode OFFSET = -1 °C;
• Setpoint value for heater = 22 °C
Presetting: 0 °C (Celsius).
2. AC SET1,2
(When air conditioner is connected/fitted)
The sensed room temperature can – during
operation of the automatic air conditioning
system – be perceived differently during cool-
ing than during heating. “AC SET” is used to
set an offset between cooling and heating. The
setting can be made in increments of 0.5 °C
within the range of 0 °C to +5 °C.
• With the rotary push button (8), select the Example:
“Set time“ symbol in the menu bar (4).
Set room temperature 23 °C;
The hour display flashes. AC SET = 2 °C
• Setpoint value for air conditioning system
• Set the hours with rotary push button (8).
= 25 °C
• The minutes display flashes when the rotary Presetting: +1°C (Celsius)
push button (8) is tapped again.
Notes:
• Set the minutes with rotary push button (8). 1 O nly available if the air conditioning system
• Tap the rotary push button (8) to confirm the and heater are connected.
value.
2 Only available if ACC is set to “ON”.
111